Getinge Ventilator terminal sterilizers (GEVs)

 
Available chamber sizes
The standard GEV & GEC Series are available in a range of chamber cross sections and depths. Smaller 600 and 900 Series machines are typically used in smaller scale facilities (such as Pharmacy production units, clinical trials and development facilities) whereas the 1400 and larger machines are used are used for bulk production using Getinge’s rack systems.
 

Below are selections of typical standard chamber sizes. Depth of 1400, 1600 & 1800 chambers is in 1250mm (49”) increments corresponding to Getinge’s standard load module size.

 

Fully Automation Systems with Versatile Programs

In common with most process equipment provided by Getinge, the GE, GEV & GEC Series sterilizers may be equipped with a choice of automation systems (as standardized options).The dedicated Getinge PACS 3000 system is provided as standard. Many thousands of these purpose designed systems are installed and in service worldwide.
 
On request, PLC systems from Rockwell / Allen Bradley™ or Siemens™ may be fitted in standard (tested, prevalidated and documented) configurations as follows:
 
Allen Bradley™ SLC 500 Series or Compact Logix™ Platform
Panelview 600, 700+ or 1000+ HMI
Siemens™ S7 CPU315 2DP Platform
TP 170b HMI
 

All GE, GEV & GEC Series sterilizers automation systems are programmed and documented according to GAMP 4 guidelines and are 21CFR Part 11 capable. All systems may be connected to network systems - for example for data storage, batch reporting, recipe handling, network printing.

 
Getinge Circulating Water Terminal sterilizers (GECs)
 
Available chamber sizes
The standard GEV & GEC Series are available in a range of chamber cross sections and depths. Smaller 600 and 900 Series machines are typically used in smaller scale facilities (such as Pharmacy production units, clinical trials and development facilities) whereas the 1400 and larger machines are used are used for bulk production using Getinge’s rack systems.
Below are a selection of typical standard chamber sizes.
Depth of 1400, 1600 & 1800 chambers is in 1250mm  (49”) increments corresponding to Getinge’s standard load module size. Custom chamber sizes are available on request.
 

Fully Automation Systems with Versatile Programs

 
In common with most process equipment provided by Getinge, the GE, GEV & GEC Series sterilizers may be equipped with a choice of automation systems (as standardized options).The dedicated Getinge PACS 3000 system is provided as standard. Many thousands of these purpose designed systems are installed and in service worldwide.

On request, PLC systems from Rockwell / Allen Bradley™ or Siemens™ may be fitted in standard (tested, prevalidated and documented) configurations as follows:

 
Allen Bradley™ SLC 500 Series or Compact Logix™ Platform
Panelview 600, 700+ or 1000+ HMI
Siemens™ S7 CPU315 2DP Platform
TP 170b HMI